S3PS Optical cable terminal positioning glue coated heat shrinkable tube
Details
Introduction | ||||
Cross-linked polyolefin heat shrinkable tube, coated with hot melt adhesive on the inner wall. It has good air tightness, resistance to temperature cycling, and resistance to chemical corrosion. The surface is covered with temperature-indicating paint to avoid excessive heating. It is suitable for the sealing protection of the incoming and outgoing wires of the cap-type optical cable joint box. |
Features | ||||
Operating temperature: -55~110 ℃ | ||||
Minimum full shrinkage temperature: 135 ℃ | ||||
Shrink ratio: 3:1 & 4:1 | ||||
Environmentally friendly,RoHS compliant | ||||
Colour: Black |
Technical Data | ||||
Property | Test Method | Value | ||
Heat shrink tube performance | ||||
Density | ASTM D792 | 1.0-1.1 g/cm3 | ||
Maximum use temperature | IEC 216 | 110 ℃ | ||
Longitudinal length change rate | ASTM D2671 | ±10% | ||
Carbon black content | ISO 11358-1 | 2.60% ± 0.25% | ||
Tensile Strength | ASTM D2671 | ≥17 MPa | ||
Breakdown elongation | ASTM D2671 | ≥350% | ||
Aging(150℃/168h) Tensile Strength Breakdown elongation | ASTM D2671 | ≥14 MPa ≥270% | ||
Water absorption (23℃/24h) | ASTM D570 | ≤0.2% | ||
Low temperature flexibility(-40℃/4h) | ASTM D2671 | No cracks | ||
Heat shock(200℃/4h) | ASTM D2671 | No dripping and no flow (heat shrink tube) | ||
Resistance to environmental stress cracking | ASTM D1693 | No cracking | ||
Dielectric strength | ASTM D2671 | ≥15 kV/mm | ||
Volume resistivity | ASTM D2671 | ≥1.0×1014Ω·cm | ||
Storage period (40℃/336 h) | — | Outer diameter or length change rate≤2% | ||
Hot color dressing | — | The color-changing paint does not change color below 180℃, and the color-changing paint finishes changing color at 250℃ | ||
Hot melt adhesive performance | ||||
Softening Point | GB/T 15332.94 | ≥115 ℃ | ||
Viscosity | HG/T 3660-1999 | ≥50000mPa·S | ||
Environmental stress cracking | Hot melt adhesive is a cracking agent(50±2)℃,48h | The sheath material sample does not crack | ||
Corrosion to copper, aluminum and steel | 120℃±2℃,16h | No corrosion | ||
Overall performance | ||||
Air tightness | YD/T 814: 1、Pressure loss: the inflation pressure in the joint box (100±5) kPa, keep it for 24 hours; 2、Air tightness: temperature: (23±3)℃, inflation pressure in the joint box (100±5) kPa, the product is just immersed below the water surface for 15 minutes | No bubbles were observed during the test or the air pressure remained unchanged after 24 hours. | ||
Temperature cycle | YD/T 814: 1、Test conditions: Above ground type -40℃ to 65℃; connector box inflation (60±5)kpa; underground type -25 to 60℃; connector box inflation (60±5)kpa; 2、Raise to high temperature at a temperature change rate of 1℃/min for 2h; reduce to room temperature and keep for 2h; reduce to low temperature and keep for 2h; finally raise to room temperature and keep for 2h; 3、A total of 10 cycles. | After the test, the air pressure does not drop by more than 5kPa; the air tightness test is passed. | ||
Chemical resistance | YD/T 814:1、Dome closure inflation (60±5)kpa; 2、Immerse the samples in 5%HCL, 5%NaOH, and 5%NaCL respectively; 3、Soaking time in each solvent is 24h | 1、Pass air tightness and pressure loss test(100 kPa); 2、Visually inspect the sample for no damage. |
Dimension | ||||
Size | As supplied(mm) | After shrink (mm) | Standard length | |
S3PS | Diameter | Diameter(Max.) | W T | m |
28/6 | 28 | 6 | 3.0 | 150/180/200 |
30/10 | 30 | 10 | 3.0 | 150/180/200 |
40/10 | 40 | 10 | 3.7 | 150/180/200 |
65/20 | 65 | 20 | 3.6 | 150/180/200 |
75/22 | 75 | 22 | 3.7 | 150/180/200 |
85/25 | 85 | 25 | 3.8 | 150/180/200 |
35/10 | 35 | 10 | 3.0 | 150/180/200 |
75/20 | 75 | 20 | 3.7 | 150/180/200 |